NEWSCheck Our Blog

Bring to the table win-win survival strategies to ensure proactive domination. At the end of the day, going forward.

Electrolysis of water to produce hydrogen + oxygen, hydrogen oxygen ignited to produce water, this process without the slightest pollution. Power: 350W. Ignition of pure hydrogen can be used for heating, easy to observe, safe and pollution-free use; Suitable for glass processing heating, jewelry processing heating, hydrogen and oxygen welding and so on.

Application It can be used to make flexible, removable partial dentures for dentistry, clinics, hospitals, factories, and so on. Specifications Mount Type: Desktop Assembly Required: Yes Material: Cast Iron Style: Modern Color: Gray, Silver, Black Voltage: AC 110V/60Hz Power: 350W Power Source: Corded Electricity Plug Type: US Standard Heating Temperature: 282-288°C/539.6-550.4°F Pressurization Time: 7 Min 30 Sec - 11 Min Heat Press Machine Bottom Bracket Size: 19.5*9.5*19.5cm/7.68*3.74*7.68in Overall Heat Press Machine Size (L*H): 46*52cm/18.11*20.47in Heating Main Part Size: 16*12*13cm/6.3*4.72*5.12in Heater Size: 24*18.2*27.5cm/9.45*7.17*10.83in Package Size: 56*39*31cm/22.05*15.35*12.20in.

Specification Voltage: AC 110V/60Hz Power: 400 watts Heating temperature: 282-288 ° C Pressurization time: 7 minutes 30 seconds - 11 minutes Packing size: 40*34*57cm Gross weight: 30kg Using Steps: 1 The function of the heater is to heat the ink cartridge at a temperature of 282-288 ° C for about 7 minutes 30 seconds - 11 minutes to melt the flexible denture material in the ink cartridge. 2 The function of the hot press is to inject molten material into a previously prepared flask. 3 The heater will beep when it is heated. Note Please read the product manual carefully before operating the machine. What's Included? 1x Heater 1x Hot Press 1x Picking Stick 1x Small Top bar 1x Big Top bar 1x Type Box 1x Box Wrench 1x Power Cord 1x Product Brochure.

BICKER.DE POWER SUPPLY FOR KARL STORZ AIDA MODEL# MV1E-5350V 350W(MAX), GOOD CONDITION PLEASE READ BELOW BEFORE PURCHASING . Disclaimer Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer. Buyers are responsible for all customs charges inclusive of any and all taxes and duties. Please be sure that the item you are purchasing can be imported into your country. "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." Medical Equipment Policy It is up to the purchaser to meet all requirements and regulation certification processes that deemed necessary per FDA or any other regulatory agencies that may be applicable. If you purchase medical, laboratory or any equipment that will be for PATIENT use, it is the BUYERS responsibility to have the equipment certified, tested or inspected prior to patient use. No exceptions. By purchasing an item, you agree to the following: We (Seller) do not state or imply the usage of the item being sold. Prior to using the item, you (Buyer) will seek if applicable the manufacture or your personal/medical care/health care provider for full details on proper usage of the item, instruction for fitting and wearing of an item if applicable, maintenance/operations, care of item or any regulatory requirements for the item. Listing descriptions are medical collectible only and equipment herein is not specified or recommended for any particular use. You (Buyer) of the item agree to use this product at his own risk and agree to hold harmless seller, and release owners, from any damage/liability he may incur due to the use of the item. Purchaser agrees that seller is not liable for any injuries or damages of any kind associated in any way with this equipment. Purchaser agrees to indemnify and hold harmless seller and seller's officers, directors, employees, agents, and shareholders against any and all claims, liabilities, obligations, demands, cost and expenses of every kind and nature, including but not limited to attorney's fees and litigation expenses, from or related to the equipment and any use thereof.

110 V 1000ml Stirring digital display thermostatic heating sleeve     I. Introduction Designing by European techniques, with its advance technology, stable performance, novel structure and good using effect, this equipment is widely used for in heating in labs of colleges, petrochemical industries, medicine, and environment protection institutions etc. Ⅱ. Characteristics 1. Cold rolling sheet stretching and spraying exterior. 2. Use advanced digital temperature control system can precisely control the temperature of the heated liquid, easy to use, high precision, temperature display intuitive. 3. Using high quality nickel-chrome heating resistance wire sealed in high temperature insulation layer. Woven into half the ball in heating sets, with characteristics of large heating area, fast warm-up, high temperature evenness, no open flame and so on. Ⅲ. Working condition Ambient temperature: 5~40℃; Ambient humidity: ≤90%; Voltage: 110V Ⅳ.Main technical parameters Model 98-II-C Capacity (ml) 50 100 250 500 1000 2000 3000 5000 Voltage(v) 110V/220V Max. use tem. 450℃ Tem. Range Ambient tem.~40℃ Sensor PT100 Working mode continuous Power(W) 80 100 150 250 350 450 600 800 (Red color is available) Ⅴ. Operation instruction a) Place the equipment on level worktable, put the sensor frame, and plug it into sensor block on the back of the instruments b) Fill a liquid container in the instrument, and set the sensor in the heated liquid. c) Use the same voltage as the machine required, and then the instrument’s screen will display the temperature of the liquid. d) Set temperature: after press “S” ,the green button “Set” indicator light, the screen display the set temperature, and press the arrow keys to select the temperature you want to use. After setting temperature, press “S” to display the actual temperature. e) When heated the red indicator light, lights off when not heated. f) When temperature rose to the set temperature at the first time, it may be washed for few degrees; it will stabilize down when the temperature came down. g) Stirring adjust: Adjust the stirring speed by turn the knob clockwise. Ⅵ. Safety attentions Connect the device to an earthed power supply to ensure safety of machine and experiment; connect the power as the machine required. This equipment is forbid to use in inflammable and explosive, poisonous and strong corrosive experiments. Make sure horizontal installation. Non-professionals are not allowed to disassemble and repair this machine. Pay attention to the set temperature while dealing with the inflammable matters. Make sure dry the resin container, if the temperature is setting too high by accident, the container would be dissolved and then fall on the heater to cause fire. Overfilled of sample will lead to overheat of working room under parts, which will dissolve the inflammable material and cause fire. While the machine is working, don’t touch the top, window and exhaust port of the device to protect from high-temperature burns.pan> Read the instruction book before operation. Ⅶ. Usage notes 1. Because of the surface of heat insulation material is coated with grease, in the first used shall first heat except when heating oil, will appear white smoke, shut off the power after heating to smokeless, when the temperature come down, it can normal use 2. When use the instrument should pour the liquid into the container firstly, and then put in the instrument to use. Ⅷ. Fault analysis Phenomenon Causation Treatment No power Poor connect of socket and plug circuit not closes. Adjust the socket and plug Adjust the circuit No heating Heating jacket wire is broke Chang heating jacket No temperature control The control panel is broke Change control panel Ⅸ. Storage and transportation Keep it in dry and clean room with good ventilation and no corrosive gas, prevent it from wetting by the rain and avoid violent collision in transportation.     Item# Description QTY Unit 020378 110v 1000ml Stirring digital display thermostatic heating sleeve 1 set On Apr-02-21 at 20:53:07 PDT, seller added the following information:

©2026 Astefal – Assistência e tratamento especializado de fisioterapia em Alagoas LTDA | CNPJ: 14.970.352/0001-84